Add to Cart
Custom Black Nitrile Rubber Diaphragm 2W320 for Electromagnetic Water Valve Medium with Water/Oil
As the diaphragm is a flexible mechanism that needs to be opened and closed frequently to control air circulation, it is required to have good flexibility and as high tightness as possible. Therefore, the material of the diaphragm is directly related to the service life and efficiency of the diaphragm.
In other words, the quality of the diaphragm will directly affect the working stability of the machine and directly affect the use cost of the equipment. Generally, the diaphragm has the promise of service life or operation times. The use of high-quality diaphragm can directly reduce the use cost of the working equipment.
Model | 2w200-20 water valve diaphragm |
Hole number for mounting | 4 |
Working temperature | -20℃--80℃ |
Working pressure | 0.2Mpa-0.6Mpa |
Working medium | Water, Clean Air |
Diaphragm working life | More than 1 million cycles |
Application | Industrial water treatment system |
Circles, squares and others are available
This specification diaphragm installation in water solenoid valve as followed sample:
Of course,the other fittings also can be available,such as solenoid coils
Description of water solenoid valve
Water solenoid valve has closed cavity, in a different location to open a hole, each hole leads to different tubing, cavity valve is among, both sides are two electromagnets, which face the magnet coil electricity body will be attracted to which side, by controlling the movement of the valve body blocked or leakage of different discharge of oil hole, and the oil hole is always open, hydraulic fluid will enter the different oil drain, and then through the oil pressure to push the cylinder piston, piston drives the piston rod, piston rod drive mechanism. This controls the mechanical motion by controlling the current in the electromagnet.
2W series water solenoid valve is the use of media pressure difference work of direct moving electromagnetic valve, it USES diaphragm structure, with open and close quickly, stable performance, easy to use, high reliability, long life and other characteristics; The valve is highly resistant to contamination.
The electromagnetic valve fault and eliminate:
(a)when electromagnetic valve does not work after the power supply:
1, check the power supply wiring whether bad -) connectors and wiring connection again;
2, check whether the power supply voltage in the plus or minus working range --) to switch to normal position;
3, whether the ring sealing off -) to welding;
4, coil short circuit, replace the coil;
5, differential pressure is not appropriate to work -) -) or replacement of proportion adjustment pressure difference electromagnetic valve;
6, fluid temperature is too high -) change of proportion of electromagnetic valve;
7, have impurities to make electromagnetic valve of the main valve core and the moving core card die -) cleaning, such as seal damage the seal and install the filter should be changed;
8, the liquid viscosity is too large, high frequency and life expectancy has to -) replacement products.
If you want know more,feel free to contact us pls.