2 1/2 Inch DMF-Z-62S SBFEC Type Right Angle Impulse Diaphragm Valve With Integral Solenoid DC24V
Application:
Electromagnetic pulse valve, also called diaphragm valve acts as a “switch” for compressed air in the dust clean blowing system for pulse bag filters. It is controlled by the electric signals from the pulse-jet control device. This system cleans the filter bags cluster by cluster with high-pressure blowing to keep the pressure resistance of the baghouse within a pre-set range, and thus ensure the processing capability and the dust-collecting efficiency of the baghouse.
Technical data of SBFEC Replacement Right Angle Impulse Diaphragm Valves:
Tips: All related accessories are also sold, like Pulse Controller, Diaphragm, Solenoid Coil and Armature Assembly.
Main dimension of DMF-Z-62S SBFEC Type Dust Collector Valve:
Detailed pictures of DMF-Z-62S SBFEC Replacement Solenoid Valve:
DMF-Z-62S right angle dust collector pulse valve installation precautions:
In the installation process, it is based on the standard. Improper installation often hinders the normal operation of the electromagnetic pulse valve. It directly affects the effect of the operation of the dust collector, and summarizes the installation and debugging of the electromagnetic pulse valve of the previous dust removal system. The common faults have the following phenomena:
1. The rated voltage of the installed electromagnetic pulse valve is inconsistent with the supplied working voltage. When energized, the electromagnetic pulse valve will not operate or the coil will burn out.
2. Before installing the electromagnetic pulse valve, be sure to purge the pipeline to ensure that there are no metal powder, rust and other impurities in the pipeline to block the electromagnetic pulse valve. The compressed air of the pipeline medium must be clean.
3. The electromagnetic pulse valve is oriented, and the reverse direction of the electromagnetic pulse valve will cause the valve to be closed and to be ventilated. The installation method should be selected according to the same model and media flow direction on the instruction manual.
4. When threading, tighten the connecting bolts and properly use the adhesive or sealing tape to prevent leakage.
5. The bolts at the connection of the electromagnetic pulse valve are not tightly sealed, and there is leakage. The compressed air cannot reach the working pressure value.