
Add to Cart
G1/4'' Inch 325.5 g Weight MSV-1028/2 Freezing & Cooling Refrigeration Solenoid Valves
The failure of cold water equipment sometimes occurs on the solenoid valve. For example, the installation direction of the solenoid valve is wrong, the dirt inside the valve body is blocked, the solenoid valve cannot be opened, etc. If these problems occur to you, you can consult us, we can all For you to solve. Of course, we also need to provide the corresponding products, and the quality of our products is strictly controlled. Our minimum order quantity is also low. Our company not only provides high quality and low price products, but also provides consulting assistance services.
Technical informations of G1/4'' MSV-1028/2 Refrigerant Control Solenoid Valve in freezer:
Model No. | Connection sizes (SAE/ODF) | Dimension | KV values | |||||||
H1 | H2 | L1 | Q | |||||||
Inch | mm | Inch | mm | Inch | mm | Inch | mm | |||
MSV-1020/2 | 1/4''SAE | 3.0 | 75 | 2.5 | 62.5 | 2.3 | 58 | 0.175 | ||
MSV-1020/3 | 3/8''SAE | 3.0 | 75 | 2.5 | 62.5 | 2.6 | 65 | 0.23 | ||
MSV-1028/2 | 1/4''ODF | 3.0 | 75 | 2.5 | 32.5 | 4.9 | 125 | 0.15 | ||
MSV-1028/3 | 3/8''ODF | 3.0 | 75 | 2.5 | 62.5 | 4.9 | 125 | 0.23 | ||
MSV-1064/3 | 3/8''SAE | 3.2 | 82 | 2.7 | 69.5 | 2.6 | 68 | 0.8 | ||
MSV-1064/4 | 1/2''SAE | 3.2 | 82 | 2.7 | 69.5 | 2.8 | 72 | 0.8 | ||
MSV-1068/3 | 3/8''ODF | 3.2 | 82 | 2.7 | 69.5 | 4.5 | 111 | 0.8 | ||
MSV-1068/4 | 1/2''ODF | 3.2 | 82 | 2.7 | 69.5 | 5.0 | 127 | 0.8 | ||
MSV-1070/4 | 1/2''SAE | 3.6 | 91 | 3.0 | 75.0 | 3.9 | 100 | 1.8 | 45 | 2.2 |
MSV-1070/5 | 5/8''SAE | 3.6 | 91 | 3.0 | 75.0 | 4.2 | 106 | 1.8 | 45 | 2.61 |
MSV-1078/4 | 1/2''ODF | 3.6 | 91 | 3.0 | 75.0 | 5.0 | 127 | 1.8 | 45 | 2.2 |
MSV-1078/5 | 5/8''ODF | 3.6 | 91 | 3.0 | 75.0 | 6.9 | 173 | 1.8 | 45 | 2.61 |
MSV-1078/6 | 3/4''ODF | 3.7 | 96 | 3.0 | 75.0 | 7.0 | 179 | 1.8 | 45 | |
MSV-1078/9 | 1 1/8''ODF | 4.5 | 115 | 3.8 | 96.0 | 9.8 | 250 | 3.1 | 80 | 10 |
MSV-1078/11 | 1 3/8''ODF | 6.8 | 172 | 5.4 | 138.0 | 10.9 | 278 | 2.8 | 68 | 16 |
MSV-1090/5 | 5/8''SAE | 4.2 | 106 | 3.0 | 78.0 | 1.7 | 120 | 2.2 | 57 | 3.8 |
MSV-1090/6 | 3/4''SAE | 4.2 | 106 | 3.0 | 78.0 | 4.9 | 124 | 2.2 | 57 | 4.8 |
MSV-1079/7 | 7/8''ODF | 3.6 | 91 | 3.0 | 75.0 | 7.5 | 190 | 1.8 | 45 | 2.61 |
MSV-1079/11 | 1 3/8''ODF | 4.5 | 115 | 3.8 | 96.0 | 11.5 | 292 | 3.1 | 80 | 10 |
MSV-1079/13 | 1 5/8''ODF | 6.8 | 172 | 5.4 | 138.0 | 10.9 | 278 | 2.8 | 68 | 16 |
MSV-1098/7 | 7/8''ODF | 4.2 | 106 | 3.0 | 78.0 | 7.1 | 180 | 2.2 | 57 | 5.7 |
MSV-1099/9 | 1 1/8''ODF | 4.2 | 106 | 3.0 | 78.0 | 8.5 | 216 | 2.2 | 57 | 5.7 |
MSV1099/11 | 1 3/8''ODF | 6.2 | 157 | 5.0 | 127.0 | 10.9 | 291 | 2.8 | 68 | 10 |
Main dimension of MSV-1028/2 Temperature Control Solenoid Valve In Ice Maker:
Producing & Testing View of MSV-1028/2 Brass Refrigeration Solenoid Valve In Air-conditioning Units:
Packing & Delivery Of MSV-1028/2 Refrigeration Electromagnetic Valve In HVAC System:
What are the important parts of a chiller refrigeration system and common faults?
The main components of the chiller refrigeration system are compressor, condenser, evaporator, expansion valve (or capillary, subcooling control valve), four-way valve, double valve, check valve, solenoid valve, pressure switch, melting plug, output pressure Regulating valves, pressure controllers, reservoirs, heat exchangers, collectors, filters, dryers, automatic shutters, shut-off valves, liquid plugs, and other components.
It is necessary to know more about the possible failures of various components of the chiller and to eliminate and repair them in time. The following describes the common faults of solenoid valves on chillers:
1. The solenoid valve cannot be opened and operated normally, or the power supply voltage is too low; or the circuit is in poor contact, that is, the circuit breaker or the coil is short-circuited, and can be inspected by a multimeter;
2. The valve of the solenoid valve is not closed tightly, or the installation direction of the solenoid valve is reversed, that is, the direction of fluid flow is opposite to the flow direction required by the solenoid valve, and the flow direction arrow on the valve body can be checked to confirm;
3. If the solenoid valve chip has dirt, the chip is stuck, causing the closure to be not tight or unable to close;
4. If the pressure difference between the inlet and outlet of the solenoid valve is greater than the valve opening capacity, the solenoid valve will not open;
Welcome to your inquiry!