3/8 Inch 4V300Series Electromagnetic Pneumatic Valve Working Medium for 40 Micron Filtered Air
Solenoid Pneumatic Valve applicate widely.Esspecially 4V Series.
1, Double control solenoid valves have memory function.
2, Internal hole adopts special processing technology which has little
attrition friction ,low start pressure and long service life.
3, No need to add oil for lubrication.
4, It is available to from integrated valve group with the base to save
installation space.
5, Affiliated manual devices are equipped to facilitate installation and debugging
6, Several standard voltage grades are optional.
7. sliding column structure, good sealing, responsive;
Model | 4V310-10 | 4V320-10 | 4V330-10 | |
Position No. | Two-Position Five-Way | Three-Position Five Way | ||
Effective sectional area | 30mm²(CV=1.68) | 18mm²(CV1.00) | ||
Port size | 3/8’’ | |||
Fluid | 40 micron filtered air | |||
Action style | Internal pilot | |||
Working pressure range | 1.2Mpa | |||
Ambient Temp | 5~50’C | |||
Voltage range | ±10% | |||
Power consumption | AC:4.5VA DC:3W | |||
Insulation and Protection | Class F IP65 | |||
Frequency | 20t/s | |||
Response time | 50ms |
Drawings of 4V310-10
Actual Coils
Application In
The following points for installation of solenoid valve are as follows:
1, installation should pay attention to the arrow on the valve body should be consistent with the media flow direction. Do not install in places where there is direct drip or splash. Solenoid valves should be installed vertically.
2, solenoid valves should be guaranteed to operate normally within the 15%-10% range of the rated voltage.
3. After installing the solenoid valve, there should be no reverse pressure difference in the pipeline. It needs to be energized several times to make it warm enough to be put into operation.
4. Solenoid valve should be thoroughly cleaned before installation. The medium should be free of impurities. Filter before valve.
5, when the solenoid valve malfunctions or cleaning, to ensure that the system continues to operate, it should install bypass devices.
Working principle
There is a close cavity in the solenoid valve, and there are through holes in different positions. Each hole leads to different tubing. There are valves in the middle of the cavity and two electromagnets on both sides. Hydraulic oil enters different drain pipes and then pushes the piston of the cylinder through the pressure of the oil. The piston then drives the piston rod, which drives the mechanical device. In this way, the mechanical movement is controlled by controlling the current of the electromagnet.
Daily maintenance of pneumatic solenoid valve:
1. Disassemble and clean the internal impurities of the pneumatic solenoid valve regularly, check whether each part of the pneumatic solenoid valve is seriously worn, and consider replacing or repairing the damaged parts according to the actual situation.
2. When disassembling the pneumatic solenoid valve, the power should be cut off and other supporting facilities should be closed first, and pay attention to the installation sequence of each part of the solenoid valve in the disassembly process.
3, pneumatic solenoid valve prone to failure problems are mainly vulnerable parts such as coils and seals, coils burned out is due to overload work, the seals themselves are vulnerable parts, mostly due to natural wear and tear in a long time of work.
4, when the pneumatic solenoid valve at work, if often vibration, it is easy to cause damage to the pneumatic solenoid valve parts, so the maintenance of the solenoid valve, but also to ensure the stability of the working environment, fixed the pneumatic solenoid valve parts regularly, such as nuts and bolts.
5. If the working environment of the pneumatic solenoid valve is open air, it may cause the rust of the pneumatic solenoid valve and parts and make the solenoid valve unable to work normally. So the need for maintenance, to ensure the stability of the performance of the operation.
6. If the pneumatic solenoid valve is important in the workplace, it shall be equipped with special maintenance personnel to ensure the working stability and low failure rate of the solenoid valve. This will make it more efficient, cost less to maintain and last longer. Pneumatic solenoid valve maintenance method, and the general class valve method is mostly similar, in the actual use and maintenance process, users can refer to the relevant instructions for appropriate maintenance and maintenance operation. This for pneumatic solenoid valve and other valve life extension has a positive effect.