Ningbo Brando Hardware Co., Ltd

Focus on your demands Offer you best solution

Manufacturer from China
Verified Supplier
10 Years
Home / Products / Refrigeration Solenoid Valve /

1/2'' Welding Type Refrigeration Solenoid Valve For Temperature Control AC/DC

Contact Now
Ningbo Brando Hardware Co., Ltd
Visit Website
City:ningbo
Province/State:zhejiang
Country/Region:china
Contact Person:MrBrandon Bao
Contact Now

1/2'' Welding Type Refrigeration Solenoid Valve For Temperature Control AC/DC

Ask Latest Price
Brand Name :BRANDO
Model Number :MSV-1078/4
Certification :CE
Place of Origin :CHINA
MOQ :1 piece
Price :negotiation
Payment Terms :L/C, T/T, Western Union,Paypal
Supply Ability :4450 sets per month
Delivery Time :4-10 days
Packaging Details :Inner Box,Carton,Pallet
Port size :1/4''SAE~7/8''ODF
Material :Brass
Power :Solenoid
Temperature of media :-35°C-105°C
Application :Refrigerant
Structure :Control
Pressure :0.05-2.5MPa
Voltage :110VAC,220VAC,24VDC,DC12V
Refrigerant :HCFC/HFC(customer specified)
Type :Normal Close
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

1/2'' Welding Type MSV-1078/4 Electromagnetic Valve Refrigeration Spare Parts For Temperature Control AC/DC

The MSV-1078/4 refrigeration solenoid valves are used in chillers to control temperature by controlling the flow of refrigerants.The chilled water circulation system is widely used: industry, agriculture, surface treatment, electroplating, laser, printing, food, beverage, cosmetics, toys, chemicals, hardware, building materials, automobiles, electronics, electrical appliances, electromechanical and other 16 industries, more than 30 Industry; high-power chillers are widely used in hotels, office buildings for central air conditioning, plastic cooling, food preservation, bath temperature, medical storage and other industries.So our MSV-1078/4 solenoid valve are widely used in industiral refrigeration system.

Technical data of MSV-1078/4 1/2 inch port size refrigeration solenoid valve:

Model number:Connection sizeDimensionKV value
H1H2L1Q
InchmmInchmmInchmmInchmm
MSV-1020/21/4''SAE3.0752.562.52.358 0.175
MSV-1020/33/8''SAE3.0752.562.52.665 0.23
MSV-1028/21/4''ODF3.0752.532.54.9125 0.15
MSV-1028/33/8''ODF3.0752.562.54.9125 0.23
MSV-1064/33/8''SAE3.2822.769.52.668 0.8
MSV-1064/41/2''SAE3.2822.769.52.872 0.8
MSV-1068/33/8''ODF3.2822.769.54.5111 0.8
MSV-1068/41/2''ODF3.2822.769.55.0127 0.8
MSV-1070/41/2''SAE3.6913.075.03.91001.8452.2
MSV-1070/55/8''SAE3.6913.075.04.21061.8452.61
MSV-1078/41/2''ODF3.6913.075.05.01271.8452.2
MSV-1078/55/8''ODF3.6913.075.06.91731.8452.61
MSV-1078/63/4''ODF3.7963.075.07.01791.845
MSV-1078/91 1/8''ODF4.51153.896.09.82503.18010
MSV-1078/111 3/8''ODF6.81725.4138.010.92782.86816
MSV-1090/55/8''SAE4.21063.078.01.71202.2573.8
MSV-1090/63/4''SAE4.21063.078.04.91242.2574.8
MSV-1079/77/8''ODF3.6913.075.07.51901.8452.61
MSV-1079/111 3/8''ODF4.51153.896.011.52923.18010
MSV-1079/131 5/8''ODF6.81725.4138.010.92782.86816
MSV-1098/77/8''ODF4.21063.078.07.11802.2575.7
MSV-1099/91 1/8''ODF4.21063.078.08.52162.2575.7
MSV1099/111 3/8''ODF6.21575.0127.010.92912.86810


Overall Dimension of MSV-1078/4 Solenoid Valve In Refrigeration Condensing Units:
1/2'' Welding Type Refrigeration Solenoid Valve For Temperature Control AC/DC

Different Connection type and size of MSV-1078/4 Refrigeration solenoid valve refrigerant flow control:
1/2'' Welding Type Refrigeration Solenoid Valve For Temperature Control AC/DC

Application of MSV-1078/4 Solenoid Valve In HVAC Refrigeration Units:
1/2'' Welding Type Refrigeration Solenoid Valve For Temperature Control AC/DC

Introduction of Water cooling and Air cooling units with MSV-1078/4 refrigeration solenoid valve:
Generally, chillers are divided into water cooling and air cooling.
The air-cooled chiller contains a water tank and a water pump, eliminating the need for cooling tower cooling. Easy to install and move. However, the environmental requirements are high. First, because it is cooled by hot air circulation, if the ventilation effect of the installation workshop is not good, it will directly affect the cooling effect of the chiller. In addition, if you want to put the chiller in a dust-free workshop with humidity requirements, it will generate a lot of water vapor on the top of the machine.

The water-cooled chiller is divided into an open chiller, a sealed type (some called a box chiller) and a screw chiller. Water-cooled chillers must be equipped with additional cooling towers and pumps to achieve better cooling. The open chiller has to be equipped with a separate water tank, which is not necessary because it has a built-in water tank. The open type is generally installed outside the workshop for easy maintenance, but because it is not aesthetically pleasing, a sealed water-cooled chiller is produced. The sealed water-cooled chiller is a box structure that is easy to install and easy to use, and is popular among the customers of Meisen Refrigeration. However, if you have a very high demand for cooling capacity, we recommend that you use a screw chiller. If you have a chiller compressor requirement of 100HP or higher, we recommend a screw chiller.
Second, the chilled water circulation refrigeration unit is equipped:
1. Compressor;
2. Pump;
3. Computer PC board, touch control, safe and convenient;
4. Thermostat: liquid crystal display temperature control electronic board;
5. Expansion valve, refrigeration solenoid valve, filter;
6. One 304 stainless steel water tank with built-in insulation material;
7. Electrical LG
8. Security protection system

Compressor delay start protection

  • Ice water pump overload and indicator
  • Compressor overload protection
  • Motor reverse protection and indicator
  • Compressor overload protection and indicator
  • Refrigerant shortage protection and indicator
  • Refrigerant high pressure safety valve
  • Bad heat protection and indicator
  • Fault alarm buzzer


Welcome to your inquiry!





























Inquiry Cart 0