
Add to Cart
2/2 Way 1/4" Inch Brass Body Water Solenoid Valve Direct-acting Control Valve 2W-025-08
2W-025-08 water valve belongs to small-caliber solenoid valve, adopts electromagnetic direct-acting valve opening structure, zero pressure difference opening valve. Membrane seal, sensitive action, reliable opening and closing.
We can offer voltage VC110V,VC220V,DC24V,DC12V,if you have special demand,pls contact us.
If you need other size or kinds of solenoid valve,we also can offer,waiting your email.
Specification
Body Material:Copper plating(Zinc alloy+Full copper coil)
Full copper(Brass body+Full copper coil)
Medium:Air,Water,Oil.
Type:Normal Closed
Oil seal material:NBR
Working Pressure:0-1.0MPa
Temperature:-5~80℃
Technical Data
Model | 2W025- | 2W040-10 | 2W160-15 | 2W200-20 | 2W250-25 | 2W350-35 | 2W400-40 | 2W500-50 |
Mode of action | Direct-acting | |||||||
Type | Normal Close | |||||||
Flow aperture mm | 2.5 | 4 | 16 | 20 | 25 | 35 | 40 | 50 |
CV | 0.23 | 0.6 | 4.8 | 7.6 | 12 | 24 | 29 | 48 |
Port Size | 1/4 | 3/8 | 2/1 | 3/4 | 1 | 11/4 | 11/2 | 2 |
Use fluid viscosity | Below 20CST |
Dimension Drawing of solenoid valve
Details of solenoid valve
Application of solenoid valve
Solenoid valve installation and use
1. Please refer to the instruction manual of the product before installation to see if it meets your requirements.
2. The pipeline should be cleaned before use. If the medium is not clean, a filter should be installed to prevent impurities from obstructing the normal operation of the solenoid valve.
3, the solenoid valve is generally one-way work, can not be reversed, the arrow on the valve is the direction of movement of the pipeline fluid, must be consistent.
4, the solenoid valve is installed in the general valve body level, the coil is vertically upward, some products can be installed arbitrarily, but it is best to be vertical when conditions permit, to increase the service life.
5. When the solenoid valve is working again in the icing site, it should be heat treated or set with insulation measures.
6. After the electromagnetic coil lead wire (connector) is connected, it should be confirmed whether it is firm or not. The contact of the electrical component should not be shaken. Looseness will cause the solenoid valve to not work.
7. The solenoid valve for continuous production is preferably bypassed for easy maintenance and does not affect production.
8. The solenoid valve after long-term deactivation should be used after clearing the condensate; when removing and washing, the parts should be placed in order and then restored.
9. If you have other questions,contact us,we will solve your problem.
please care the products details at our website, any confuse please contact us or Note your request online. Big quantity purchase ,please contact our online service to ask more economic shipping way or discuss the more pretty price.
Welcome your inquiry