2/2 Way Normal Closed Solenoid Valve /2" Inch Stainless Steel Water Valve 2S-500-50
Water solenoid valve is applied to waterway control, such as irrigation, running spring, water plant. 2S500-50 solenoid valve adopts diaphragm sealing structure, sensitive action, large flow, simple structure, convenient maintenance, excellent waterproof performance.
Specification of solenoid valves
Model | 2S500-50 |
Port size | 2" |
Valve body material | Stainless steel |
Fluid | Air, water, oil,gas |
orifice size | 50mm |
Acting type | Normally closed type |
CV value | 48 |
Fluid viscosity limit | Below 20CST |
Voltage | 220V AC |
Seal material | NBR, EPDM, Viton |
Mini order quantity | 100 piece |
Quality Assurance | 8~10 year |
Service response | within 24 hours |
OEM | acceptable |
Packing | plastic bag , standard export package. Or Customized |
Delivery | Ningbo Port,5~25 workdays after payment |
Certificates | CE |
Model | 2S160-15 | 2S200-20 | 2S250-25 | 2S350-35 | 2S400-40 | 2S500-50 |
Acting Type | Direct acting , Normally closed | |||||
Orifice Size | 16 mm | 20 mm | 25 mm | 35 mm | 40 mm | 50 mm |
CV Value | 4.8 | 4.8 | 12 | 24 | 29 | 48 |
Port Size | 1/2" | 3/4" | 1" | 1-1/4" | 1-1/2" | 2" |
Dimension Drawing of 2S-500-50
Professional factory
Application
Installation Precautions
1. When installing, please pay attention to the arrow on the valve body should be consistent with the flow direction of the medium. Do not install in places where there is direct dripping or splashing. The solenoid valve should be installed vertically upwards.
2. The solenoid valve should ensure normal operation within the range of 15%-10% of the rated voltage of the power supply voltage.
3. After the solenoid valve is installed, there must be no reverse pressure difference in the pipeline. It needs to be powered on several times to make it suitable for use.
4. The solenoid valve should be thoroughly cleaned before installation. The medium to be passed should be free from impurities. Install the filter in front of the valve.
5. When the solenoid valve is faulty or cleaned, a bypass device should be installed to ensure the system continues to operate.
Q1 you are manufacturer or trading company?
We are professional manufacturer.
Q2 How about the dilivery time?
Different quantity in 5-30days.
Q3 Can you produce according to the samples?
Yes,we can produce by your samples or technical drawing.
If you have more question,pls contact us,we will solve your problems.
please care the products details at our website, any confuse please contact us or Note your request online. Big quantity purchase ,please contact our online service to ask more economic shipping way or discuss the more pretty price.
Welcome your inquiry!